The scanning head support TVU 7.2 was designed for on site meter testing together with the photo-electric scanning head SH 11.

The EMP 1.3 Quick Connection Device is used together with Electricity Meter Test Systems, and is especially recommended for situations where the time factor is of importance. It enables electricity meters to be mounted and connected rapidly for the purpose of their adjustment, test and verification.

The voltage presence indicator is a lamp drawing the attention of the operator to the presence of dangerous voltages.
The voltage presence indicator is a lamp drawing the attention of the operator to the presence of dangerous voltages – both single and three phase – on a meter test station installation. When the voltage
exceeds 50 VAC, the red warning lamp is illuminated intermittently.

The HT 2010 wireless hand held terminal is designed for recording meter-specific data at meter test systems.
The Hand Held Terminal HT 2010 makes the entering of meter data considerably easier, allowing meter data directly to be entered at the meters under test.

The ICT 1.3 three-phase Isolation Current Transformer is used on multi position test benches, when three-phase meters with closed links between the current and voltage measuring circuits (C-P links) are to be tested.

Advantages
• Wide current range from 25 mA up to 200 A
• Output power max. 100 VA
• High accuracy class 0.05 by electronic error compensation
• Overload protected

The ICT 2.3 three-phase Isolation Current Transformer is used on multi position test benches, when three-phase meters with closed links between the current and voltage measuring circuits (I-P links) are to be tested.

Advantages
• Wide current range from 10 mA up to 200 A
• Output power max. 100 VA
• High accuracy class 0.05 by electronic error compensation
• Overload protected

The IMP-IF1 interface adapter is suitable for interfacing
MTE reference standards with meters
having retransmitting contacts, open-collector
transistor outputs or true S0-outputs to allow full
testing of meters with these types of outputs interfaces.
IMP-IF 1 functions
• Active input for testing S0 outputs, according
to the DIN 43864 standard
• Input for testing passive pulse outputs such
relay contacts prone to bounce or open collector
transistor outputs
• Input for testing active outputs

The SH 11 model scanning head was especially designed both for scanning of the marks on the rotating discs of mechanical meters or simulated disc marks on LCD displays and for detection of light emitting diodes (LED’s) of electronic meters. The choice of operation with mechanical or electronic meters is made by simple rotation of a selection switch. The precision optical lens is designed to make the scanning head insensible to external light. Its compact, robust construction makes the head equally suitable for use in stationary test consoles as well as for use with mobile and portable equipment. The impulse output of the scanning head delivers a positive output pulse of the duration 0.5 ms.

The SH 2003 photoelectric scanning head is suitable for use with both LED impulse electronic meters and Ferraris meters, selectable via a switch. Due to its high performance and robust construction it is suitable for both test consoles and portable systems.